Keysight Agilent HP 4291B

Keysight Agilent HP 4291B

1.8 GHz Impedance Material Analyzer

The Keysight Agilent HP 4291B is one of our refurbished 1.8 GHz Impedance Material Analyzers.

Price: Please Call



Click to email this item to a friend Click to print this product


Keysight Agilent HP 4291B Features:

  • 1 MHz to 1.8 GHz
  • Independent parameter selection in 2 channels
  • Direct read-out permittivity, permeability (option)
  • Versatile analysis (temperature, cole-cole plot, relaxation time)
  • Sweep parameters (frequency, ac level, dc bias, temperature)

The Keysight Agilent HP 4291B RF impedance/material analyzer provides a total solution for high-accuracy and easy measurement of surface-mount components and dielectric/magnetic materials. The Keysight Agilent HP 4291B uses a direct current-voltage measurement technique, opposing the reflection measurement technique, for more accurate impedance measurement over wide impedance range. Basic impedance accuracy is ± 0.8%. High Q accuracy enables low-loss component analysis. An internal synthesizer sweeps frequency from 1 MHz to 1.8 GHz with 1 mHz resolution. A 1.8-m error-less cable connects the analyzer to a test station so you can extend your test point away from the analyzer without losing accuracy. Advanced calibration and error compensation function eliminate measurement error factors in fixtures and assure high accuracy and repeatability at DUT/MUT. The Keysight Agilent HP 4291B also provides automatic level control and monitor of test signals by using IBASIC programming function; devices can be measured under a constant voltage or current. Measure bias dependent impedance characteristics with optional dc bias (up to 40 V and 100 mA). At the push of a button, the built-in Equivalent Circuit Analysis Function automatically calculates the circuit constant values of five circuit models. The Keysight Agilent HP 4291B has two measurement channels; each channel can be set to measure a single (e.g. Z) or dual (e.g. Z-theta) impedance parameter. The color TFT with split-display can show both active traces and memory traces (stored in RAM). A built-in floppy disk drive stores programs and test data in either LIF or MS-DOS format. With built-in IBASIC, you can control external test equipment such as a temperature chamber or wafer prober directly from the Agilent 4291B. You do not need a separate instrument controller.

Keysight Agilent HP 4291B - Option Descriptions

Option Item Description
001 Add DC Bias
002 Material Measurement
011 Delete High Imp Test Head
012 Add Low Imp Test Head
013 High Temperature High Imp Test Head w/Fixture Stand
014 High Temperature Low Imp Test Head w/Fixture Stand
1A2 Keyboard Less
1D5 High Stability Frequency Reference