Keysight Agilent HP N1610A/N1660A

Keysight Agilent HP N1610A/N1660A

Service Advisor Test Tablet w/N1660A Dual DS1/0 Module

The Keysight Agilent HP N1610A/N1660A is one of our used Service Advisor Test Tablets with Dual DS1/0 Module.

Price: Please Call

Refurbished

Quantity:   

Click to email this item to a friend Click to print this product

 

Keysight Agilent HP N1610A Features:

  • Modular:
    • Supports 2 single modules or 1 dual test module
    • Hot swappable
  • Display:
    • 7.2" diagonal 640 x 480 color VGA backlighted dual scan LCD
  • User Interface:
    • Graphical User Interface
    • Touchscreen
    • Navigation Keys: Direction ( ­ ¯ ¬ ® ),Enter, Display/Audio
    • LEDs: On/Off (green), External Charging/
    • Battery Low (green, red)
    • Stylus
  • Memory:
    • RAM: 16MB
    • Flash-ROM: 12MB
  • Operating System:
    • Microsoft Windows® CE 2.0 or later
    • Flash File System for non-volatile results and configuration storage
  • Processor:
    • Hitachi SH-3
    • Continuous time and date clock
  • Remote Control:
    • Remote Services provides SCPI command line interface (option)
  • PC-Cards Supported:
    • Type-I and II
    •  V.90 56K Modem PC Card (option)
    •  10BaseT Ethernet LAN PC Card (option)
    •  10MB Flash-ROM PC Card (option)
  • Data and File Management:
    • Local:
      • Store and recall results
      • Store and recall configurations and test suites
    • Remote:
      • via Service Advisor Companion software (compatible with Windows® 95/ 98, Windows NT® 3.51 or later)
  • Upload results:
    • Upload and download configurations and test suites
    • Download program Flash-ROM updates


Keysight Agilent HP N1660A Features:

  • Keysight Agilent HP N1660A test module for the Service Advisor test tablet simplifies T1 and DS0 testing by providing complete analysis of line conditions and status on both sides of the circuit. The Keysight Agilent HP N1660A Service Advisor Dual DS1/0 Test Module provides 2xRx and 2xTx, T1 and Nx56kbps and Nx64lbps BERT.
  • Features
  • Unframed, ESF, SF and SLC-96 testing  
  • T1/DDS Testing  
  • Monitors and inserts errors, alarms, loop codes and tones  
  • Audio, input and output  
  • Signaling and pulse mask measurement options  
  • View All Key Results On One Screen
  • Quickly and easily synchronize to full-duplex T1 circuits. Simultaneously view the status of both sides of the T1. The Dual Line DS1/0 Test Module features color coded "soft LED" indicators, color coded meters providing results and summary data.
  • Simultaneously Monitoring and BER Testing
  • The Dual Line DS1/0 Test Module features a full compliment of standard BERT patterns and flexible user-programmable patterns. BER test on both directions of the circuit.
  • Automate BER Testing Sequences
  • Quickly perform multi-pattern and bridge tap test sequences. Inject errors. The Dual Line DS1/0 Test Module features user-programmable BER test sequences and status display area.
  • Complete Loopback Capabilities
  • Control loopback activation and deactivation. Supports in-band and out-of-band loop codes. Use standard and user-programmable loop codes.
  • Oscilloscope Views of the Received T1 Signal
  • The Dual DS1/0 Test Module's pulse mask measurement option provides a scope view of the T1 signal. Quickly compare with industry-standard masks. Measure standard parameters for further detailed analysis.
  • Ongoing Background Event Logging
  • Document turn-ups, corrective action, and trouble scan lines. Scroll through results. Date and time stamp results. Save results in file.
  • Troubleshoot PBX Signaling
  • Display on-hook/off-hook status of all 24 channels. Test E-M, ground start, loop start, or mixed trunks. View time and date of events.

The Keysight Agilent HP N1610A/B Service Advisor Test Tablet is Keysight Agilent HP's newest portable platform for Telco, residential access and line qualification applications. The Keysight Agilent HP N1610A servicea dvisor's advanced Windows CE operating system, touch sensitive color VGA screen and consistent graphical user interface provide an easy to use and versatile tool for installing and maintaining services at the central office and outside plant. The Keysight Agilent HP N1610A and N1660A Dual Line DS1/0 Plug-in Module combine sophisticated, full-duplex analysis with unprecedented flexibility and simplicity of operation. The Keysight Agilent HP N1610A and Keysight Agilent HP N1660A provide a lightweight, battery-powered solution for dual T1 testing, full and fractional T1 BERT testing, and optional signaling and pulse mask measurements.With its powerful Graphical User Interface (GUI) and its simple and easy operation, the Service Advisor Portable Test Tablet is the ideal tool for the outside plant. Its intuitive user interface allows the operator to quickly install and maintain service. Battery power allows operation where AC power is not available or convenient. Optional software application packages enable technicians to store and recall data and information in databases, spreadsheets and documents. The rugged design of the Service Advisor Portable Test Tablet enables it to stand up to years of demanding field use. Technicians and engineers can use the Service Advisor Portable Test Tablet to develop and verify network elements in the laboratory. Its consistent user interface and modular design help users rapidly switch test tasks. The advanced operating system enables users to develop test sequences which can be rapidly rolled out in the field. With its SCPI command line interface control, users can easily create test sequences which operate the test set from a serial port, a modem or a LAN. Central Office (CO) users will find the power and flexibility of the Service Advisor Portable Test Tablet ideal for installing and maintaining services. The simple GUI operation enables wide first tier field deployment and 2nd/3rd tier regional support. With flash memory capability, CO personal can create test suites which can be downloaded into the test set for field testing. Once the data is collected it can then be recalled, analyzed and transferred to a PC.