Philips PM2811

PM2811 Philips DC Power Supply

30V/10A/60W, Power Supply

The PM2811 is a 60 Watt DC Power Supply from Philips. Supplies DC Voltage and Current to test, design, and troubleshoot electric and electronic circuits. Applications include Burn In, QA, ATE, Research, Design, and Education to name a few.

Price: Please Call

Refurbished

Quantity:   

Click to email this item to a friend Click to print this product

 

NIST Calibration Pricing - $115.00

Philips PM2811 Features:

  • OUTPUT module 30V/10A/60W
    • Output Voltage range 0 to 30 V
    • Output Current range 0 to 10 A
    • Output Power 60 W
    • Overvoltage protection range 2 to 32 V
  • Accuracy (at calibration temperature)
    • Output Voltage +/- 0.04 % of setting + 10 mV
    • Output Current +/- 0.1 % of setting + 50 mA
    • Over Voltage Protection +/- 0.5 % of setting + 150 mV
  • Temperature coefficient
    • Output Voltage (0.016 % of setting + 2 mV)/K
    • Output Current (0.05 % of setting + 2 mA)/K
  • Long term drift (in an 8 hour period)
    • Output Voltage 0.04 % of setting + 5 mV
    • Output Current 0.05 % of setting + 10 mA
  • Programming Resolution (12bit)
    • Output Voltage 7.5 mV/LSB
    • Output Current 2.5 mA/LSB
    • Over Voltage Protection 7.5 mV/LSB
  • Source Effect (for any line voltage change within rating)
    • Voltage +/- (0.01 % of setting + 2 mV)
    • Current +/- (0.02 % of setting + 2 mA)
  • Load Effect (load change 10 % to 90 % or 90 % to 10 % full load)
    • Constant Voltage +/- (0.01 % of setting + 5 mV)
    • Constant Current +/- (0.02 % of setting + 5 mA)
  • Load cross regulation Negligible for both voltage and current
  • Output Noise (PARD)
    • Constant Voltage pp/rms 15 mV/3 mV
    • Constant Current rms 10 mA
    • Switching Frequency approx. 20 kHz approx.
  • READBACK ACCURACY:(referred to the output terminals)
  • Accuracy (at calibration temperature)
    • Voltage +/- (0.05 % + 25 mV)
    • Current +/- (0.1 % + 30 mA)
  • Measuring Resolution (12 bit)
    • Voltage resolution to interface 7.5 mV
    • Current resolution to interface 2.5 mA
    • Voltage resolution to display 10 mV
    • Current resolution to display 10 mA
    • Max. Current at Reverse voltage 10 A
    • REMOTE SENSE > 0.25 Volt drop per lead (at open sense connections, the output voltage will not be more than 3 V above the programmed value)
    • DYNAMIC OPERATION ÆI=1 A between 1 and 10A between 0.5 and 5A between 1 and 10A
      • Settling band +/- 50 mV
      • dI/dt < 1 A/?s
      • Overshoot < 150 mV
      • Recovery time < 1 ms
  • Programming response (measured with resistive load)
    • Up (0 V to max. output) 100 ms @ 2 A
    • Up (0 V to max. output) 50 ms @ (no load)
    • Down (max.output to 1 V) 100 ms @ 2 A

Philips PM2811 - Option Descriptions

Option Item Description
13