Mixed signal oscilloscopes have two kinds of inputs. They have a small number of analog channels (typically two to four) and a larger number of digital channels (typically 16). Mixed signal oscilloscopes test equipment by combining the capabilities of a digital storage oscilloscope and a logic analyzer. They are less complex to use than logic analyzers, but lack some of the advanced digital measurement functions. Most mixed signal oscilloscopes have components such as digital-to-analog converters, embedded systems, and control systems.

When you test equipment, you can set the trigger on most mixed signal oscilloscopes across digital and analog channels. Mixed signal oscilloscopes enable you to accurately time-correlate both.

Items 1-24 of 68

Page
per page
Set Descending Direction
  1. 54622D Agilent Mixed Signal Oscilloscope
    54622D Agilent Mixed Signal Oscilloscope
    $295.00
    Condition: Used
    Channels: 2+16
    Frequency: 100 MHz
    Record Length: 4 MPts
    Sampling Rate: 200 MS/s

  2. 54645D Agilent Mixed Signal Oscilloscope
    54645D Agilent Mixed Signal Oscilloscope
    $325.00
    Condition: Used
    Channels: 2+16
    Frequency: 100 MHz
    Record Length: 1 MPts
    Sampling Rate: 400 MS/s

  3. 54833D Agilent Mixed Signal Oscilloscope
    54833D Agilent Mixed Signal Oscilloscope
    Condition: Used
    Channels: 2+16
    Frequency: 1 GHz
    Record Length: 4 MPts
    Sampling Rate: 4 GS/s
  4. 54832D Agilent Mixed Signal Oscilloscope
    54832D Agilent Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+16
    Frequency: 1 GHz
    Record Length: 4 MPts
    Sampling Rate: 4 GS/s
  5. 54621D Agilent Mixed Signal Oscilloscope
    54621D Agilent Mixed Signal Oscilloscope
    Condition: Used
    Channels: 2+16
    Frequency: 60 MHz
    Record Length: 4 MPts
    Sampling Rate: 200 MS/s
  6. MSO7104A Agilent Mixed Signal Oscilloscope
    MSO7104A Agilent Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+16
    Frequency: 1 GHz
    Record Length: 8 MPts
    Sampling Rate: 4 GS/s
  7. MSOX4154A Keysight Mixed Signal Oscilloscope
    MSOX4154A Keysight Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+16
    Frequency: 1.5 GHz
    Record Length: 4 MPts
    Sampling Rate: 5 GS/s
  8. MSO6054A Agilent Mixed Signal Oscilloscope
    MSO6054A Agilent Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+16
    Frequency: 500 MHz
    Record Length: 2 MPts
    Sampling Rate: 4 GS/s
  9. 54642D Agilent Mixed Signal Oscilloscope
    54642D Agilent Mixed Signal Oscilloscope
    Condition: Used
    Channels: 2+16
    Frequency: 500 MHz
    Record Length: 8 MPts
    Sampling Rate: 2 GS/s
  10. MSOX4024A Keysight Mixed Signal Oscilloscope
    MSOX4024A Keysight Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+16
    Frequency: 200 MHz
    Record Length: 4 MPts
    Sampling Rate: 5 GS/s
  11. MSOX3104A Keysight Mixed Signal Oscilloscope
    MSOX3104A Keysight Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+16
    Frequency: 1 GHz
    Record Length: 2 MPts
    Sampling Rate: 5 GS/s
  12. MSO6104A Agilent Mixed Signal Oscilloscope
    MSO6104A Agilent Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+16
    Frequency: 1 GHz
    Record Length: 2 MPts
    Sampling Rate: 4 GS/s
  13. MSOX3054A Keysight Mixed Signal Oscilloscope
    MSOX3054A Keysight Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+16
    Frequency: 500 MHz
    Record Length: 2 MPts
    Sampling Rate: 4 GS/s
  14. MSO7104B Agilent Mixed Signal Oscilloscope
    MSO7104B Agilent Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+16
    Frequency: 1 GHz
    Record Length: 8 MPts
    Sampling Rate: 4 GS/s
  15. MSO7052B Agilent Mixed Signal Oscilloscope
    MSO7052B Agilent Mixed Signal Oscilloscope
    Condition: Used
    Channels: 2+16
    Frequency: 500 MHz
    Record Length: 8 MPts
    Sampling Rate: 4 GS/s
  16. MSOX2004A Keysight Mixed Signal Oscilloscope
    MSOX2004A Keysight Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+8
    Frequency: 70 MHz
    Record Length: 100 kPts
    Sampling Rate: 2 GS/s
  17. MSOX92004A Agilent Keysight HP Mixed Signal Oscilloscope
    MSOX92004A Agilent Keysight HP Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+16
    Frequency: 20 GHz
    Record Length: 2 GPts
    Sampling Rate: 80 GS/s
  18. MSO6032A Agilent Mixed Signal Oscilloscope
    MSO6032A Agilent Mixed Signal Oscilloscope
    Condition: Used
    Channels: 2+16
    Frequency: 300 MHz
    Record Length: 2 MPts
    Sampling Rate: 2 GS/s
  19. MSO7054B Agilent Mixed Signal Oscilloscope
    MSO7054B Agilent Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+16
    Frequency: 500 MHz
    Record Length: 8 MPts
    Sampling Rate: 4 GS/s
  20. MSOX93204A Keysight Mixed Signal Oscilloscope
    MSOX93204A Keysight Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+16
    Frequency: 33 GHz
    Record Length: 40 MPts
    Sampling Rate: 80 GS/s
  21. MSOX2012A Keysight Mixed Signal Oscilloscope
    MSOX2012A Keysight Mixed Signal Oscilloscope
    Condition: Used
    Channels: 2+8
    Frequency: 100 MHz
    Record Length: 100 kPts
    Sampling Rate: 2 GS/s
  22. MSOS604A Agilent Keysight HP Mixed Signal Oscilloscope
    MSOS604A Agilent Keysight HP Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+16
    Frequency: 6 GHz
    Record Length: 800 MPts
    Sampling Rate: 20 GS/s
  23. MSO6034A Agilent Mixed Signal Oscilloscope
    MSO6034A Agilent Mixed Signal Oscilloscope
    Condition: Used
    Channels: 4+16
    Frequency: 300 MHz
    Record Length: 2 MPts
    Sampling Rate: 2 GS/s
  24. MSOX3102A Keysight Mixed Signal Oscilloscope
    MSOX3102A Keysight Mixed Signal Oscilloscope
    Condition: Used
    Channels: 2+16
    Frequency: 1 GHz
    Record Length: 2 MPts
    Sampling Rate: 5 GS/s