1060 AEMC Insulation Meter

Used

Additional Features:

  • Test voltage combinations of 50V, 100V, 250V, 500V and 1000V
  • Insulation measurements to 4000GO (4TO)
  • Direct measurement of DAR and PI values
  • Direct measurement of sample Capacitance
  • Display of test voltage and run time
  • Programmable test run times and PI times
  • Smooth and Alarm functions
  • Automatic test inhibition (if live sample >25V)
  • Automatic discharge after use with voltage display
  • Large dual display with time, voltage and measurement
  • Bright blue electroluminescent backlight
  • Battery powered
  • AC rechargeable NiMH batteries – run while recharging
  • RS-232 interface for direct printing of results (serial output)
  • 128kB memory to store measurements in specific files
  • Remote operation of megohmmeter through PC
  • Includes DataView software for data storage, real-time display, analysis and report generation
  • Auto power-down when not in use
  • Remote operation with optional test probe
  • Rugged dual wall field case with detachable lead/accessory pouch

Applications

  • Test insulation on cables, transformers, motors, insulators and wiring installations
  • High resistance or absorption tests
  • Spot reading tests
  • Timed resistance measurements
  • Dielectric Absorption Ratio (DAR) and Polarization Index (PI) tests
  • Low insulation test range for testing old or flooded installations
  • Motor insulation resistance measurements
  • Continuity checks and low resistance measurements
  • Computer controlled production line testing
  • Predictive maintenance by storing results in PC for trend analysis

Insulation Tests

Test Voltage:

  • 50V: 0.002MΩ to 200GΩ
  • 100V: 0.004MΩ to 400GΩ
  • 250V: 0.01MΩ to 1000GΩ (1TΩ)
  • 500V: 0.02MΩ to 2000GΩ (2TΩ)
  • 1000V: 0.04MΩ to 4000GΩ (4TΩ)
  • Short Circuit Current: <6mADC
  • Accuracy: 2kΩ to 400GΩ: ±5% of Reading ± 3cts; 400GΩ to 4TΩ: ±5% of Reading ± 10cts
  • DAR (1 min/30 sec): 0.000 to 9.999
  • PI (10 min/1 min & user programmable): 0.000 to 9.999
  • Capacitance Check: 0.005 to 4.999μF
  • Programmable Run Time R(t): 1 to 59 minutes
  • Smooth Function
  • Discharge After Test 
  • Discharge Voltage Display 
  • Voltage Tester /Safety Check: 0 to 1000VAC/DC
  • Voltage Warning Indicator: >25V 
  • Test Inhibition Yes: >25V 
  • Guard Terminal: Yes

Resistance Tests

  • Range: 0.01Ω to 400kΩ 
  • Test Voltage: 12.4VDC
  • Short Circuit Current: <6mADC
  • Accuracy: ±3% of Reading ± 3cts

Continuity Tests

  • Range: 0.01Ω to 39.99Ω 
  • Test Current: ≥200mA from 0.01 to 20.00Ω 
  • Accuracy: ±3% of Reading ± 4cts
  • Buzzer: Yes

Power Source 

  • Rechargeable NiMH batteries

Display

  • Backlight: Blue electroluminescent
  • Display Size: 4 x 2.25" (102 x 57mm)
  • Digital Display: Two 4000-count
  • Analog Bargraph: 31-segments

Communication

  • Remote Test Probe Operation: Yes (optional)
  • Report Print Out on Printer: Preset format
  • Storage of Readings over Time R(t): 128kB memory
  • Programmable Reading Intervals: 5 sec to 10 min
  • Test Voltage Display: Yes 
  • Elapsed Test Time Display: Yes
  • Test Voltage Lock-out: User programmed
  • Storage of Test Results: 128kB memory with RS-232
  • Bi-directional Software: Yes, DataView® (included)
  • PC Operation of Megohmmeter: Yes

Safety

  • Safety Rating: EN 61010-1, 600V Cat. III, EN 61557
  • Double Insulation: Yes
  • CE Mark: Yes

DataView Software for Model 1060

  • Configure all functions of the Megohmmeter Model 1060
  • Print reports of all test results
  • Select test voltage and run tests from your computer with a simple click and execute process
  • Capture and display data in real time
  • Retrieve data from the instrument’s memory:
  • Over 1500 insulation resistance measurements
  • Over 4000 resistance measurements
  • Display DAR and PI ratios
  • Plot graphs of manual and timed tests
  • Include your analysis in the comments section with the report
  • Store a library of setups for different applications

Reports may be displayed on your PC and printed. Each report includes all test results in a tabular and graphic format, as well as operator and test site information. Comments typed in at time of storage will also be included.

The DataView® Software provides a convenient way to configure and control Megohmmeter tests from your computer. Through the use of two clear and easy-to-use dialog boxes, all functions of the Model 1060 can be configured and tests can be initiated. Results can be displayed in real time and stored in your PC. Reports can be printed along with the operator’s comments and analysis.

A simple press of the download button from either the setup or run dialog boxes will show all test results stored in the Model 1060. Each test will be stored as its own file and may be given its own unique file name.

Minimum System Requirements

  • Windows®98/2000/ME/XP or Windows®NT 4.0
  • 128MB of RAM (256MB recommended) Windows®98/2000/ME/XP or Windows®NT 4.0; 256MB RAM for Windows®XP
  • 35MB of hard disk space (200MB recommended)
  • CD Rom drive

The AEMC Megohmmeter Model 1060 is an innovative family of professional 1000V Digital/Analog insulation testers. The 1060 is designed to facilitate testing quickly and accurately by incorporating automatic measurement features and user-friendly functions.

Measurements are displayed on a large dual-display LCD with bargraph for quick viewing of changes or trends. Resistance readings are displayed on the larger display, and a smaller display is used for test voltage at the sample, test run times (mm:ss), or alarm set points – all accessible at the press of a button. A family of visual indicators for safety and information also compliments the displays. A bright blue electroluminescent backlight makes for clear readings in dark areas.

The 1060 automatically provides the DAR and PI ratios directly on the display. User defined PI time intervals may also be programmed. The user may even select DAR or PI functions before the test, and the megohmmeter will stop at the appropriate time and display the results. Test run times from 1 second to 59 minutes are also directly programmable. The tested sample Capacitance is available at the end of each insulation resistance test.

For specific applications and operator or equipment safety, test voltages may be disabled to avoid any errors. An automatic test inhibitor prevents testing on live circuits above 25V. Discharge test voltage may be displayed at the completion of each test.

A memory feature in the 1060 permits storing, recalling and displaying of resistance values taken at user specified intervals during a test.

The Model 1060 has an RS-232 interface and a more extensive memory function, which permits the storage of results in files specific to the device under test. Additionally, it also has a built-in document function, which prints out a preformatted report on a serial or parallel printer. A standard software package (DataView®) enables the user to display graphs and results for complete documentation and reporting. The Model 1060 can also be programmed and run by a PC with this software. This enables tailored test programs, remote operation and storing of information directly into a PC.

The AEMC 1060 is built into a double insulated field case with a detachable accessory pouch.

More Information
ManufacturerAEMC
ConditionUsed
Test Voltage1 kV
No manuals are currently available. Search all of our available manuals here.