117 Fluke Multimeter

New
Special Price
$266.79
Regular Price
$289.99
In Stock
Ships Today
Free Shipping
 
background image

Technical Data

Fluke 117

Electrician’s Multimeter

with Non-Contact Voltage

Features include:

 VoltAlert

technology for non-contact voltage detection

 AutoVolt automatic ac/dc voltage selection

 LoZ: helps prevent false readings due to ghost voltage

 Large white LED backlight to work in poorly lit areas

 True-rms for accurate measurements on non-linear loads

 Measures 10 A (20 A overload for 30 seconds)

 Resistance, continuity, frequency and capacitance

 Min/Max/Average to record signal fluctuations

 Compatible with optional magnetic hanger (ToolPak

) for

hands free operation

 CAT III 600 V safety rated

Compact true-rms meter for 
commercial applications

The Fluke 117 is the ideal meter for 
demanding settings like commercial 
buildings, hospitals and schools. The 117 
includes integrated non-contact voltage 
detection to help get the job done faster. 

General specifications

Accuracy is specified for 1 year after calibration, at operating
temperatures of 18 °C to 28 °C, with relative humidity at
0 % to 90 %.
The accuracy specifications take the form of:
± ( [ % of reading ] + [ counts ] )

Maximum voltage between any 
terminal and earth ground

600 V

Surge protection

6 kV peak per IEC 61010-1 600 V
CAT III, Pollution Degree 2

Fuse for A input

11 A, 1000 V FAST Fuse
(Fluke PN 803293)

Display

Digital: 6,000 counts, updates 4/sec

Bar graph

33 segments, updates 32/sec

Operating temperature

-10 °C to + 50 °C

Storage temperature

-40 °C to + 60 °C

Battery

9 volt Alkaline, NEDA 1604A/
IEC 6LR61

Battery life

400 hours typical, without backlight

N10140

R

Actual size

background image

Accuracy Specifications

Measurement

Range

Resolution

Accuracy 

± ([% of reading] + [counts]) 

DC millivolts

600.0 mV

0.1 mV

0.5 % + 2

DC volts

6.000 V

0.001 V

0.5 % + 2

60.00 V

0.01 V

600.0 V

0.1 V

Auto volts

600.0 V

0.1 V

2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)

AC millivolts

1

 

true-rms

600.0 mV

0.1 mV

1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)

AC volts

1

 true-rms

6.000 V

0.001 V

1.0 % + 3 (45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)

60.00 V

0.01 V

600.0 V

0.1 V

Continuity

600 Ω

1 Ω

Beeper on < 20 Ω off > 250 Ω; detects

opens or shorts of 500 µs or longer.

Ohms

600.0 Ω

0.1Ω

0.9 % + 2

6.000 kΩ

0.001 kΩ

0.9 % + 1

60.00 kΩ

0.01 kΩ

600.0 kΩ

0.1 kΩ

6.000 MΩ

0.001 MΩ

40.00 MΩ

0.01 MΩ

1.5 % + 2

Diode test

2.000 V

0.001 V

0.9 % + 2

Capacitance

1000 nF

1 nF

1.9 % + 2

10.00 µF

0.01 µF

100.0 µF

0.1 µF

9999 µF

1 µF

100 µF to 1000 µF

1.9 % + 2

> 1000 µF

5 % + 20

Lo-Z capacitance

1 nF to 500 µF

10 % + 2 typical

AC amps true-rms 
(45 Hz to 500 Hz)

6.000 A

0.001 A

1.5 % + 3

10.00 A

0.01 A

20 A overload for 30 seconds max.

DC amps

6.000 A

0.001 A

1.0 % + 3

10.00 A

0.01 A

20 A overload for 30 seconds max.

Hz (V or A input)

2

99.99 Hz

0.01 Hz

0.1 % + 2

999.9 Hz

0.1 Hz

9.999 kHz

0.001 kHz

50.00 kHz

0.01 kHz

Notes:

1

All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-
zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3

at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.

2

Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.

Ordering  
Information

Fluke-117

Electrician’s
Multimeter with
Non-Contact Voltage

Included
TL75 Test leads, holster, User’s
manual and 9 V battery (installed).

More Information
ManufacturerFluke
ConditionNew
AC Voltage600 V
DC Voltage600 V
Resolution3.5
TypeHandheld
No manuals are currently available. Search all of our available manuals here.