Features:
- Accuracy: (Voltage and Current True RMS)
- DC & 20 Hz to 5 KHz: = +0.1 % of reading +6 counts
- 5 KHz to 10 KHz: +0.5% of reading +6 counts
- 10KHz to 20KHz: +0 75% of rdg +6 counts - useable to 50 KHz with typicality
- 0.75% error per 10 KHz
- Maximum Input: 1000VDC or RMS AC, 3000 V pk/pk
- Displays: 4 1/2 Digit (20.000 courts) 7 segment LEDs
- Watts Accuracy: 25°C +5°C, 1 year
- DC & 20 Hz to 5 KHz: +0.25 % of reading +6 counts
- 5 KHz to 10 KHz: +0.5% of reading +0.5% of range
- 10 KHz to 20 KHz: +0.75% of reading +0.75% of range
- 20 KHz to 50 KHz: add 0.75% per 10 KHz above 20 KHz
- Power Factor Response: Unity (1.000) to zero (0.000)
The 2300L is a power analyzer from Valhalla Scientific.
Manufacturer | Valhalla Scientific |
---|---|
Condition | Used |
Looking for other manuals? Search all of our available manuals here.