Additional Features:
- Volts, ohms, amps, continuity, diode test
- mA current range for improved low-current readings
- 0.3% basic dc voltage accuracy
- 3200 count resolution
- Digital display with analog bargraph
- Integral molded holster with Flex-Stand
- Touch Hold to capture readings
- 10 MΩ input impedance, analog bar graph
- Sleep mode preserves battery life
Specifications:
Basic Accuracy (± % of reading)
DC Voltage
- Range: 320 mV -1000V
- Accuracy: 0.3%
- Best Resolution: 0.1 mV
AC Voltage
- Range: 3.2V -1000V
- Accuracy: 2%
- Best Resolution: 1 mV
DC Current
- Range: 32 mA -10A
- Accuracy: 1.5%
- Best Resolution: 0.01 mA
AC Current
- Range: 32 mA -10A
- Accuracy: 2.5%
- Best Resolution: 0.01 mA
Resistance
- Range: 320Ω - 32 MΩ
- Accuracy: 0.5%
- Best Resolution: 0.1Ω
Safety
- 1000V, AC/DC maximum voltage between any terminal and earth ground. Conforms to Cat III 600V and CAT II 1000V per ANSI/ISA-S82.01-94, EN 61010-1: 1993, CSA C22.2 No. 1010.1-92. Protected from overvoltage transients to 6 kV
Surge protection
- 6 kV peak per IEC 1010.1-92.
Fuse protection
- 440 mA, 1000V AC/DC Min interrupt rating 10 kA.; 11A, 1000V AC/DC Min interrupt rating 17kA.
Environmental Specifications
- Operating Temperature: 0°C to +50°C
- Storage Temperature: -40°C to +60°C
- Humidity (Without Condensation): 0% - 90% (0°C - 35°C); 0% - 70% (35°C - 50°C)
- Operating Altitude: 2000 m
The Fluke 77-III offers exactly the right fit for a wide range of measurements. The 77-III is truly an all-round performer. The 77-III has all the features and functions for a wide range of industrial applications packaged in an ergonomic case with integrated holster.
Manufacturer | Fluke |
---|---|
Condition | Used |
AC Voltage | 1 kV |
DC Voltage | 1 kV |
Resolution | 3.5 |
Type | Handheld |