Additional Features:
- Frequency range: 9 kHz to 2.9 GHz
- Frequency counter: Eliminate the need for a separate frequency counter with the built-in frequency counter with ±2.1 kHz accuracy at 1 GHz (±7.6 kHz from 0 °C to 50 °C).
- Multiple resolution bandwidth filters: Optimize the tradeoffs of speed, sensitivity and the separation of closely spaced signals with your choice of 10 resolution bandwidth filters beginning at 1 kHz.
- 142 dB amplitude measurement range: Measures signals directly with -112 dBm to +30 dBm amplitude measurement range.
- One-button measurement routines: Save time, setup, and training with one button measurement routines such as Adjacent Channel Power, signal bandwidth and Third Order Intercept (TOI).
- Phase noise of 105 dBc/Hz at 30 kHz offset: Uncover small signals close to carriers with an internal phase noise that will not get in your way.
- Dual interfaces: Operate remotely and print directly with the optional dual interfaces that combine either an GPIB or RS-232 port with a parallel (Centronics) port.
The Agilent 8594L is a low-cost, but full-featured, frequency accurate RF spectrum analyzer designed to meet your general purpose measurement needs. The easy-to-use interface provides access to more than 200 built-in functions.
The Agilent 8594L has an optional built-in tracking generator that measures the scalar characteristics of your components with the optional built-in tracking generator and the Agilent 85714A scalar measurements personality.
Data storage can be to internal memory, where over 50 traces and states may be saved, or to memory cards through the optional memory-card reader. Data can be directly output to a printer or plotter through the optional GPIB, RS-232, or parallel printer interfaces.
Built-in Measurement Capability
Third-order intercept, percent AM, and “N” dB bandwidth are just a few of the built-in measurements. These measurements are performed at the press of a single softkey. Results are displayed onscreen. And the downloadable program (DLP) capability lets you write your own built-in measurements using the DLP editor and an external keyboard.
Measurement Personalities
Measurement personalities are application-specific DLPs that are loaded into the analyzer through the optional card reader. They provide measurement routines and a user-interface specific to the application. A scalar measurements personality customizes the 8590L with optional built in 1.8 GHz tracking generator, and a cable TV measurements personality equips the 8590L-Series with one-button RF measurements for CATV service and system monitoring.
MIL-T-28800 Conformance
The 8590 series spectrum analyzers conform to the environ-mental specifications of MIL-T-28800 class 5 to insure reliable and accurate performance in portable environments as well as indoors. Compliance with the MIL-T-28800 standards of vibration, temperature, humidity, and shock provide assurance that the 8590 series will withstand the rigors of field use.
Manufacturer | Agilent, HP, Keysight |
---|---|
Condition | Used |
Frequency | 2.9 GHz |
001 | 75 Ohm Input Impedance |
---|---|
003 | Memory Card Reader |
004 | Precision Frequency Reference |
009 | LO and Sweep + Tune Outputs on Rear Panel |
010 | 9 kHz to 2.9 GHz Tracking Generator with 50 Ohm output impedance |
011 | 9 kHz to 2.9 GHz Tracking Generator with 75 Ohm output impedance |
015 | Protective Tan Operating/Carrying Case with Shoulder Strap |
016 | Protective Yellow Operating/Carrying Case with Shoulder Strap |
021 | HP-IB Interface |
023 | RS-232 Interface |
026 | Frequency Extension to 26.5 GHz with APC-3.5 Connector |
027 | Frequency Extension to 26.5 GHz with N-Type Connector |
041 | HP-IB and Parallel Interface |
042 | Protective Soft Carrying Case/Back Pack |
043 | RS-232 and Parallel Interface |
050 | Improved Amplitude Accuracy for NADC bands |
051 | Improved Amplitude Accuracy for PDC bands |
052 | Improved Amplitude Accuracy for PHS |
053 | Improved Amplitude Accuracy for CDMA |
0B0 | No manuals |
101 | Fast Time Domain Sweeps |
102 | AM/FM Demodulator with Speaker and TV Sync Trigger Circuitry |
103 | Quasi-Peak Detector and AM/FM Demodulator With Speaker |
105 | Time-Gated Spectrum Analysis |
110 | CT2 Demodulator |
111 | Group Delay and Amplitude Flatness |
112 | DECT Demodulator |
119 | Noise Figure |
130 | Narrow Resolution Bandwidths |
140 | Narrow Resolution Bandwidths and Precision Frequency Reference |
151 | DSP, Fast ADC and Digital Demodulator |
160 | PDC/PHS/NADC/CDMA Firmware for Option 151 |
161 | NADC-TDMA firmware ROM for Option 151 |
163 | GSM/DCS1800 Firmware for Option 151 |
180 | TV Picture Display |
301 | TV Sync Trigger Capability/Fast Time-Domain Sweeps and AM/FM Demodulator |
40 | Front cover w/ storage |
711 | 500 to 75 Ohm Matching Pad |
713 | Reduced Frequency Accuracy |
8ZE | Refurbished spectrum analyzer |
908 | Rack Mount Kit Without Handles |
909 | Rack Mount Kit With Handles |
B70 | BenchLink Spectrum Analyzer |
H01 | Unlisted custom house option |
J66 | Improved Absolute Amplitude Accuracy Specification of +/-1dB in PCS 1900 |
R53 | Improved Amplitude Accuracy for CDMA-Retrofit kit |
UK6 | Commercial Calibration Certificate with Test Data |