9100S-B-156 Fluke Calibrator

New
$3,089.00
Free Shipping
 

Features:  

  • Temperature range to 375°C (707°F) is perfect for checking RTDs, thermocouples, and small bimetal thermometers in the field
  • With a proprietary Hart Scientific temperature controller, it has a display resolution of 0.1°, an accuracy of ±0.5°C, a stability of ±0.1°C, and a stabilization time of just five minutes
  • Simple and convenient, plug it in, switch it on, set the temperature with the front-panel buttons, and insert your probe into the properly sized well
  • Compare the reading of your device to the display temperature or to an external reference, and the difference is the error in your device
  • Despite its small size (2-1/4" high and 5" wide) and light weight, it out-performs every dry-well in its class
  • Block "B" features four different size wells (1/8", 3/16", 1/4", 3/8")

Applications:

  • Ideal for the following applications: Laboratory, Education, R&D, Calibration Labs, Field Calibration

Specifications:

  • Temperature Range - 35 to 375°C?(95 to 707°F)
  • Accuracy - ±0.25°C @ 50°C; ±0.25°C @ 100°C; ±0.5°C @ 375°C
  • Stability - ±0.07°C @ 50°C; ±0.1°C @ 100°C; ±0.3°C @ 375°C
  • Well-to-Well Uniformity - ±0.2°C with sensors of similar size at equal depths within wells
  • Well Depth - 4" (102mm); 1/16" (1.6mm) hole is 3.5" (89mm) deep
  • Stabilization Time - 5 minutes
  • Heating Time - Ambient to 375°C: 9.5 minutes
  • Cooling Time - 375°C to 100°C: 14 minutes

The Fluke 9100S-B-156 is a dry-well. Since we introduced the world's first truly handheld dry-well, many have tried to duplicate it—in vain. Despite its small size (2¼ inches high and 5 inches wide) and light weight, the 9100S outperforms every dry-well in its class in the world.  It's simple and convenient, too. Anyone can learn to use one in less than 15 minutes. It has a range to 375 °C (707 °F) and is perfect for checking RTDs, thermocouples, and small bimetal thermometers in the field.  Plug it in, switch it on, set the temperature with the front-panel buttons, and insert your probe into the properly sized well. Compare the reading of your device to the display temperature or to an external reference, and the difference is the error in your device. With a proprietary Hart Scientific temperature controller, the 9100S has a display resolution of 0.1 degrees, an accuracy of ±0.5 °C, a stability of ±0.1 °C, and a stabilization time of just five minutes.

More Information
ManufacturerFluke
ConditionNew
No manuals are currently available. Search all of our available manuals here.