DSX2-5000QI/GLD Fluke Networks Copper

New
$28,603.99
Free Shipping
 

Fluke Networks DSX2-5000QI/GLD Versiv 2 CableAnalyzer with OLTS Quad and Fiber Inspection, Integrated Wi-Fi, 1-Year Gold Support

Features:

  • Fluke Networks DSX2-5000QI/GLD Versiv 2 CableAnalyzer with OLTS Quad and Fiber Inspection, Integrated Wi-Fi, 1-Year Gold Support
  • Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards
  • ProjX system manages job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly
  • Taptive user interface simplifies set-up, and eliminates errors
  • Versiv modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  • Analyze test results and create professional test reports using LinkWare management software
  • Graphically displays the source of failures including

The DSX CableAnalyzer Series copper cable certifiers enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down – setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand.

As part of the Versiv cabling certification product family, the DSX CableAnalyzer Series copper cable certifiers provides accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements. The difference between being profitable or not is just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy, making jobs easier to manage, and getting to system acceptance faster. It’s not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.

ProjX™ Management System Manages Complex Jobs with Ease

Managing the testing of multiple jobs with multiple teams, testers, and requirements is time consuming and a source of errors.

Increasingly larger jobs make project organization more important than ever. The new ProjX management system on the DSX CableAnalyzer Series copper cable certifiers provides individual project files for all job specific details to be saved under a simple name, eliminating the need to re-enter job specific details after starting a project. This minimizes set-up errors or lost files when switching from one job to another or utilizing multiple testers on a single job. In addition, it provides test results by cable ID, merges any changes without duplicates and defaults to the last copper or fiber module installed. ProjX management system provides real time status to completion on each job with a 0-100% scale and gives the operator the option to isolate any test requiring a second look and helps to assure nothing is overlooked. The "Fix Later" selection creates a punch list or automatic to do list for correcting any workmanship issues. ProjX enables project managers and crew leaders to be truly efficient.

Performs with Unsurpassed Speed

  • Eight second Cat 6A test time and the fastest way to submit your certification results

No tester offers so much speed for so many tests. Complete copper certification to Cat 6A in 8 seconds or certify two fibers at two wavelengths in just 3 seconds. Endorsements by cabling vendors worldwide assure that Versiv is the fastest way to project completion and system acceptance. Quickly get a Pass or Fail result and easily review individual test parameters by value or drill into specific area on a graph.

MPTL Certification

There may be scenarios where a typical four-connector channel is not used when connecting these types of devices– especially those that reside in the ceiling space where it is impractical to install a faceplate. Instead, there is just one patch cord in the telecommunications room and the permanent link is terminated at the other end with a plug so it can plug directly into the device, essentially eliminating the equipment cord. This creates what is now known as a Modular Plug Terminated Link, or MPTL.

The DSX CableAnalyzer™ is capable of certifying MPTL by using a patch cord adapter on one end and a permanent link on the opposite end

Specifications

DSX CableAnalyzer Series Specifications

Cable Types

  • Shielded and unshielded pair LAN cabling:  TIA Cat 3, 4, 5, 5e, 6, 6A, 100 Ω ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω

Standard Link Interface Adapters

  • Permanent link adapters:  Plug type: shielded RJ45  Optional Plug type: Tera
  • Channel Adapters: Jack type: shielded RJ45 Optional Jack type: Tera, GG45 

Test Standards

  • TIA:  Cat 3, 4, 5, 5e, 6, 6A, 8 per TIA 568 Series
  • ISO/IEC:  Class C, D, E, EA, F, FA, I/II certification per ISO/IEC 11801 Series
  • Maximum frequency:  DSX-5000 1000 MHz

General Specifications

  • Autotest Time: DSX-5000: Full 2-way Autotest of Cat 5e or 6/Class D or E: 9 seconds Full 2-way Autotest of Cat 6A/Class EA: 10 seconds

Support test parameters (The selected test standard determines the test parameters and the frequency range of the tests):  Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-tocrosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)

Input protection: 

  • Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
  • Display:  5.7 in LCD display with a projected capacitance touchscreen

Case

  • High impact plastic with show absorbing overmold

Dimensions

  • Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)

Weight

  •   Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)

Main unit and remote

  • Lithium ion battery pack, 7.2 V

Typical battery life

  • 8 hours

Charge time*

  • Tester off: 4 hours to charge from 10 % capacity to 90 % capacity

Languages supported

  • English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian

Calibration

  • Service center calibration period is 1 year

Integrated Wi-Fi

  • Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz)

Fluke Networks CertiFiber Pro Optical Loss Test Set Specifications

Power Meter Specifications

Input Connector

  • Interchangeable connector adapter (LC standard, SC, ST and FC optional)

Detector Type

  • InGaAs

Wavelengths

  • 850 nm, 1300 nm, 1310 nm, 1550 nm

Power Measurement Range

  • 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
  • Power Measurement Uncertainty1,2:  < +/- 5% +/- 32 pW
  • Measurement Linearity3:  < ± 0.1 dB

Re-calibration Period:  1 year

1. +/- 100 pW at 850 nm

2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 μm and NA = 0.14 for 9/125 μm. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST.

3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up.

Loss/Length Specifications

Testing Speeds (excludes referencing times)

  • CertiFiber Pro Multimode Modules CertiFiber Pro Singlemode Modules

Smart Remote mode

  • < 3 seconds (2 wavelengths, one direction, auto wavelength detection)
  • Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
  • Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)

Input/Output Connectors

  • Interchangeable connector adapter (LC standard, SC, ST and FC optional)
  • Launch Condition1,2
  • Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1

Fiber Types Tested

  • 50/125 µm or 62.5/125 µm singlemode

Source Type and Wavelengths

  • LED source 850 nm ± 30 nm 1300 nm ± 20 nm
  • Fabry-Perot laser diode 1310 nm ± 20 nm 1550 nm ± 30 nm

Maximum Length Measurement

  • 12 km 130 km

Length Measurement Accuracy

  • ± 1.5 m plus ± 1 % of length ± 1.5 m plus ± 1 % of length

Output Power (Nominal)

  • ≥ -24 dBm with EF-TRC ≥ -4 dBm

Output Power Stability3

  • ± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes
  • ± 0.1 dB over 8 hours ± 0.08 dB over 15 minutes

1. At the output of the EF-TRC

2. Variations between EF measurement equipment may occur but EF compliance can be expected with a 95% confidence factor

3. Relative to power level after 15 minute warm up – at constant temperature

Loss/Length Specifications (continued)

  • Source Wavelengths: 850 nm, 1300 nm, 1310 nm, 1550 nm
  • Power Measurement Range: 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
  • Power Measurement Uncertainty1, 2:  < +/- 5% +/- 32 pW
  • Measurement Linearity3: < ± 0.1 dB

Re-calibration Period:  1 year

1. +/- 100 pW at 850 nm

2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850

Selected Specifications

Visual Fault Locator (VFL)

Title:  Requirement

Output Power:  >-5 dBm <0 dBm  SMF-28 singlemode fiber

Continuous wave

  • SC/UPC connector
  • Operating Wavelength: 650 nm nominal

Output Modes

  •  Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)

Connector Adapter

  • 2.5 mm universal

Laser Safety

  • Class II CDRH Over operating temperature range 

Environmental Specifications

Title:  Requirement

  • Operating Temperature: -18° C to 45° C
  • Storage Temperature:  -30° C to +60° C

Operating Relative Humidity

  • % RH without condensation
  • 0 % to 90 %, 32 °F to 95 °F (0° C to 35° C)
  • 0 % to 70 %, 95 °F to 113 °F (35° C to 45° C)

Vibration

  • Random, 2 g, 5 Hz-500 Hz

Shock

  • 1 m drop test with and without module and adapters

Safety

  • CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition + Amendments 1, 2
  • Pollution Degree:  2

Altitude

  • Operating: 4,000 m; storage: 12,000 m
  • EMC:  EN 61326–1

Ships With:

  • 1 Versiv Mainframe & Remote
  • (2) DSX-5000 CableAnalyzer Modules
  • (2) CertiFiber Quad OLTS Modules
  • Set of Cat 6A/Class EA Permanent Link Adapters
  • Set of Cat 6A/Class EA Channel Adapters
  • (2) Headsets
  • (2) Hand straps
  • (2) Shoulder Straps
  • Carry Case
  • USB Interface Cable
  • Versiv Open Source Software CD
  • (2) AC Chargers
  • (2) Universal Couplers
  • USB Video Inspection Probe w/ 4 Tips
  • (2) Quick Clean Cleaners (1.25/2.50 mm)
  • (2) LC/LC Simplex Adapters
  • SC/LC EF-Compliant MM TRC Kit 50 µm
  • SC/LC SM TRC Kit
  • TRC Carry Case
  • Statement of Calibration
  • Getting Started Guides
  • Includes 1 year of Gold Support from Fluke Networks
More Information
ManufacturerFluke Networks
ConditionNew
Looking for other manuals? Search all of our available manuals here.