  • 30kV contact discharge level
  • Single impulse mode
  • Simple operation
  • Parameter change during operation using “+” and “-” keys
  • Internal program memory
  • Backlit LCD display
  • Electronic polarity change
  • Compact design
  • Fulfills ALL standard requirements
  • Load and save predefined or customized tests
  • Programmable level and polarity ramp
  • Low weight standalone generator
  • Battery powered
  • Highest Test Levels
  • Light and easy to use
  • Standard (0.7nS - 1nS) or Fast ESD (ca. 300pS) events
  • Remote control and software upgrade through standard interface
  • Individually calibrated discharge modules and networks
  • Wide range of discharge modules (DM) and discharge networks (DN) sold separately

Benefits

  • Get Testing Faster - Minimum learning time, Easy to follow interface, No big case unit, full mobility
  • Save Time - Reduce setup time with automated test routines, real parameter change, ideal development tool
  • Upgrade on Site - Optimize usage, calibrated extensions exchanged on site
  • Keep Testing - 8 hours time between battery charges
  • Only Need One Tester - Expandable to many applications
  • Cost effective solution to meet many test requirements
  • Low cost and rapid extension to 30kV
  • Save unnecessary development time, no overtest
  • ESD events realised exactly as in standard
  • Increase quality of test object
  • Always calibrated, ALL high voltage elements are in the module
  • Real time parameter change, Ideal development tool
  • Save operator time with the automated test routines and test report facility
  • No operator fatigue due to ergonomic design and light weight
  • Unparalleled reliability and system up-time
  • Increase reliability of test object (EUT)

Specifications

  • Construction: Fully portable, no additional basic unit
  • Control: LCD and 6 menu buttons, 1 trigger button
  • Maximum voltage: 16 kV or 30 kV, depending on modules chosen
  • Voltage steps: 100 V - test
  • Discharge polarity: Positive, negative, alternating
  • Discharge modes: Contact discharge (CD) and air discharge (AD)
  • Discharge frequency CD: Max. 20 Hz, (pulse every 0.05, 0.1, 0.2 … 99 s)
  • Discharge frequency AD: ≥ 30 Hz or more, for ex. with DM1, DN1, other
  • Counter: Pre-selectable, 1 to 29999
  • Discharge detection: Selectable, count pulses or count discharges
  • Holding time: ≥ 5 s
  • Trigger: Manual, automatic, remote
  • Ramps: Voltage, polarity
  • Reporting with TEMA: Automatic report sequence, amplitude, polarity
  • Power supply: 10 x AA rechargeable batteries or mains

Standards

  • IEC 61000-4-2
  • IEC 61340-3-1:
  • IEC 61340-3-2
  • ISO 10605
  • MIL-STD-883
  • MIL-STD-331
  • ANSI C63.16
  • EIA/JESD22-A114-B
  • EIA/JESD22-A115-A
  • SAE J551-15

ESD3000 mainframe

  • Mains adapter: 95 – 250 V (50/60 Hz)
  • Power consumption: ON < 20 VA, standby < 5 VA
  • Temperature range: 15 – 35 °C
  • Humidity: 30 – 60 % non-condensing
  • Air pressure: 86 – 106 kPa
  • Carrying case dimensions: 46 x 41 x 17 cm

Electrostatic Discharge (ESD) is the most common test procedure applied to any electronic or electrical equipment.

Used extensively to test:

  • Commercial products
  • Industrial systems
  • Military electronics
  • Automotive electronics
  • Fuses and detonators
  • Railway electronics
  • Avionic equipment qualification
  • Telecom equipment
  • Electronic components

The easily changeable and fully calibrated discharge networks, quickly adapt ESD3000 to the requirements of any new application.

ESD3000 is designed with the user in mind. The modular design allows configuration according to customer wishes, addition of more networks when adding applications and easy extension from 16kV to 30kV using the same generator. Automatic network recognition means ESD3000 is always ready.

ESD3000RM32

  • Relay module with high voltage and polarity switch
  • Relay module for ESD3000 needed for all Discharge Network (DN) Extensions
  • Relay module with high voltage and polarity switch. Circuit for generating the first current peak
  • AD and DC Requires ESD3000 with minimum one DN

Discharge Modules (DMx) up to 16kV Air / 10kV Contact Discharges

ESD3000 required-Available Extensions

  • DM1 (150pF, 330 Ohm)
  • DM2 (330pF / 2000 Ohm)
  • DM4 (100pF / 1500 Ohm)
  • DM6 (100pF / 1500 Ohm)
  • DM7 (200pF / 0 Ohm)

Discharge Networks (DNx) up to 30kV Air- and Contact Discharges

ESD3000 & RM32 required-Available Extensions

  • DN1 (150pF / 330 Ohm)
  • DN2 (330 pF, 2000 Ohm)
  • DN3 (150 pF, 2000 Ohm)
  • DN4 (500 pF, 5000 Ohm)
  • DN5 (500 pF, 500 Ohm)
  • DN6 (330 pF, 330 Ohm)

The original 30kV battery powered generator with a unique system of changeable modules. Flexibility and power combined.

AA battery powered

Long life standard battery. Up to 8 hours on full battery charge. Readily available in any store.

Extend testing capability

Add calibrated modules to maintain the system value. Unique modules and accessories for special applications.

Electronic polarity change

Single key press switches polarity before and during the test.

Compact solution

Ergonomic hand-held tester without additional base unit. Program directly on generator.

More Information
ManufacturerEMC Partner
ConditionUsed
No manuals are currently available. Search all of our available manuals here.