Additonal Features:
- Data Error Analyzer (BERT)
- Test Pattern: Pseudorandom sequences of 63, 511, 2047, 215-1, and 220-1; all marks, all spaces and 1:3; QRSS pattern provided by T1 interface
- Interface Emulation: DTE or DCE
- Bit Rate: 100 b/s to 14.0 Mb/s with appropriate interface
- Internal Standard Clock Frequencies: 1.2, 2.4, 4.8, 9.6, 19.2 56, 64 kHz, 1.544, 2.048, 3.152, 6.312 MHz
- External Clock: Accepts external clock through the data interface module or a rear panel BNC connector
- Frequency Counter: 200 Hz to 16 MHz
- Block Length: .4, 1, 4, 10, 40 and 100 k bits
- BER Test Length: 105, 106, 107, 108, 109 bits and Auto
- BER Range: 1.0 x 10-10 to 1.0 x 10-0
- Error Insertion: Single logical errors or a constant 1.0 x 10-3 rate
- Real-Time Clock: Date and time clock, battery powered
- LED Indicators DTE Mode: Sync, Sync Lost, Gen Clk Actvy, DM (DSR), RR (RLSD), CS (CTS), TM, Rcv Data Inv, Rcv Data and Rcv Clock
- LED Indicators DCE Mode: Sync, Sync Lost, Gen Clk Actvy, TR (DTR), RS (RTS), LL, RL, Tx Data Inv, Tx Data and Tx Clock
- Printer Interface: RS-232 serial ASCII format
- Audio Indicator: Beeps on the occurrence of errors, sync losses, and BER measurement completion
Applications:
- For Testing: T-Carrier Systems, Multiplexers, Digital Radio Circuits, Fiber Optic Systems, Satellite Communications Systems, DDS, Modems.
- In Such Locations As: Central Office, Tech Control Centers, End User Sites, Laboratories, Earth Stations.
- During: Installation, Acceptance Testing, Maintenance and Fault Isolation, Production Testing, Hardware Development and Evaluation, Remote Unattended Testing.
The Acterna FIREBERD 2000 gives comprehensive error analysis results along with simultaneous measurement capability. The FIREBERD 2000 measures Tx and Rcv measurements and employs RS-232 and IEEE-488 remote control.
Manufacturer | Acterna |
---|---|
Condition | Used |
40540 | DS1/T1 Interface Adapter |
---|---|
42522 | Combined Data Interface Module |
6001 | DS1Wideband Jitter Measurement |
6002 | DS1 Jitter Spectral Analysis |
6003 | DS1 Jitter Generation |
6004 | Clock Recovery |
6005 | IEEE-488 Remote Control |
6006 | Precision Time Base |
6007 | Wideband Jitter Measurement and Generation |
6008 | Jitter Spectral Analysis |
6009 | ANSI T1.403 PRMs |
6010 | Frame Relay New Unit Option |
6011 | Frame Relay Factory Upgrade |