I400S Fluke Clamp Meter
New
$364.99
Additional Features:
- Companion to your scope or power quality meter to measure up to 400 A AC
- Only current clamp available with a CAT IV 600 V/CAT III 1000 V safety rating
- Specially designed to offer maximum utility in a compact shape
- Take accurate current readings without breaking the circuit
- Soft non-slippery overmold handle
- Optional PM9081/001 BNC/Banana adapter for DMM's
- Two ranges: 40 A and 400 A, 10 and 1 mV/Amp output
- Max. conductor Ø 32 mm
- Nominal current range: 40 A Range: 0.5 A to 40 A; 400 A Range: 5 A to 400 A
- Basic accuracy: 40 A Range: 2% + 0.015 A (45-400 Hz); 400 A Range: 2% + 0.04 A (45-400 Hz)
- Typical bandwidth: 40 A Range: 5 Hz-10 kHz; 400 A Range: 5 Hz - 10 kHz
- Output level(s): 40 A Range: 10 mV/A; 400 A Range: 1 mV/A
- Crest factor: 40 A Range: ≤ 3; 400 A Range: ≤ 3 to 300 A, ≤ 2.5 to 400 A
- Safety: CAT IV, 600 V, CAT III, 1000 V
- Maximum non-destructive current: 1000 V AC
- Maximum conductor size: 32 mm (1.25 inches)
- Output cable length: 2.5 m (8.2 ft)
- Common Mode Voltage: 1000 V ac rms from earth ground, in compliance with EN61010
- Input Load Impedance (of host instrument): > 1 M Ω in parallel with up to 47 pF
- Maximum Non-destructive Current: 1000 A
- Duty Cycle: 0.5 A to 400 A continuous
- Influence of Adjacent Conductor: < 9.0 mA/A
- Influence of Conductor Position in Jaw Opening: ± 1.0 % of reading + 0.05 A
- Altitude: Operating: 2000 m; 2000 m to 4000 m, derate category rating to 1000 V CAT II/600 V CAT III, Non-operating: 12000 m
- BNC adapter
- Dimensions: 150 x 70 x 30 mm
- 1-Year Warranty
Phase shift 40 A Range
- 0.5 to 1 A: Unspecified
- 1 A to 5 A: 4°
- 5 A to 10 A: 3°
- 10 A to 20 A: 3°
- 20 A to 40 A: 2°
- 40 A to 400 A: NA
Phase shift 400 A Range
- 0.5 to 1 A: NA
- 1 A to 5 A: NA
- 5 A to 10 A: Unspecified
- 10 A to 20 A: 2°
- 20 A to 40 A: 2°
- 40 A to 400 A: 1.5°
The i400s is compatible with any Fluke Multimeter or any other current measurement device that has the following features:
- BNC or Banana inputs
- Input accuracy of 2 % or better to take full advantage of the accuracy of the Current Clamp.
- Input impedance of > 1 M Ω in parallel with up to 47 pF
The Fluke i400S AC current clamp with BNC output extends the functionality of portable oscilloscopes or power quality meters to measure up to 400 A AC. Fluke current clamps extend the current ranges of digital multimeters, power quality analyzers, and portable oscilloscopes and are available for both AC and AC/DC environments. The Fluke i400s is specially designed to offer maximum utility in a compact shape and is the only current clamp available with a CAT IV 600/ CAT III 1000 V safety rating.
Manufacturer | Fluke |
---|---|
Condition | New |
Amps | 400 A |
Volts | 600 V |
Looking for other manuals? Search all of our available manuals here.