N9020A Agilent Analyzer
Additional Features:
Functionality:
- 20 Hz to 3.6, 8.4, 13.6, or 26.5 GHz; internal preamplifier options up to 26.5 GHz
- 25 MHz (standard) or 40 MHz (optional) analysis bandwidth
- Basic EMI precompliance measurement capability available, including CISPR 16-1-1 bandwidths, detectors, amplitude correction factor, band preset, tune & listen at marker, and limit lines
Performance:
- ±0.23 dB absolute amplitude accuracy
- +20 dBm third order intercept (TOI)
- -166 dBm displayed average noise level (DANL) with preamplifier
- -78 dB W-CDMA ACLR dynamic range (with noise correction on)
Measurement Applications & Software:
- MXA supports over 25 measurement applications, covering cellular communication, wireless connectivity, digital video and general purpose.
- Advanced analysis of more than 70 signal formats, software runs inside the MXA
- MATLAB® data analysis software for general purpose data analysis, visualization, and measurement automation.
- Agilent's PowerSuite one-button power measurements included as standard
- Automation & Communication Interface
- LXI class C compliant, SCPI and IVI-COM
- USB 2.0, 1000Base-T LAN, GPIB
- Programming remote language compatibility with PSA, 8566/68, and 856x
- Common X-Series user interface / Open Windows® XP operating system
Automation & communication interface:
- LXI compliant, SCPI and IVI-COM
- USB 3.0, 1000Base-T LAN, GPIB
- Programming remote language compatibility with PSA, 8566/68, and 856x
- Common X-Series user interface / Open Windows 7 operating system (standard)
- Migrate your existing MXA from Windows XP to Windows 7
The MXA is designed to accelerate the development of new wireless devices for quick delivery to manufacturing and the marketplace. It has the versatility to easily adapt to your evolving test requirements by addressing multiple formats, generations and devices.
Real-time spectrum analyzer capability can be added as an upgrade to new and exisiting MXAs to help you capture and understand the most elusive signals in an increasingly complex signal environment. Coupled with 160 MHz of wideband analysis bandwidth, the MXA allows you to make accurate analysis of next-generation wireless communications and connectivity signals.
The N9020A MXA signal analyzer is a member of the X-Series spectrum analyzers, which is an evolutionary approach to signal analysis that spans instrumentation, measurements and software. It gives you the flexibility to satisfy your business and technical requirements across multiple products and programs - now and in the future.
Manufacturer | Agilent, HP, Keysight |
---|---|
Condition | Used |
205 | Basic VSA-lite |
---|---|
235 | Pre-amplifier |
333 | X-Series analyzer connectivity |
3FP | Amplitude correction and limit lines |
4FP | TOI and harmonics |
503 | 9 kHz to 3.0 GHz Frequency Range |
507 | Frequency range, 9 kHz to 7.0 GHz |
513 | Frequency range, 10 Hz to 13.6 GHz |
526 | 20 Hz to 26.5 GHz |
550 | Frequency range, 3 Hz to 50 GHz |
5FP | ACP 18 Carrier |
6FP | TV Trigger and IQ Analyzer |
AYA | Vector modulation analysis |
B1X | Increase analysis bandwidth from 10/25 to 160 MHz |
B25 | 25MHz Maximum bandwidth |
B40 | 40MHz Maximum bandwidth |
BBA | Baseband Analog I/Q |
CRP | Arbitrary IF output |
DP2 | Digital processor with 2 GB capture memory |
EA3 | Electronic attenuator (Frequency range 20 Hz to 3.6 GHz) |
EDP | Enhanced display package |
EMC | Basic precompliance EMI features |
EP1 | Enhanced Phase Noise Performance |
EP3 | Enhanced phase noise |
EP4 | Enhanced phase noise performance, CXA |
ESC | External source control |
FS1 | Fast sweep capability |
FSA | Mechanical attenuator, 2 dB steps, 0 to 70 dB |
LFE | Low Frequency Enabled (allows frequency range to 3 Hz) |
LNP | Low noise path |
MPB | Microwave preselector bypass |
N9020A-B25 | Analysis bandwidth, 25 MHz |
N9060A 2 TO 7 FP | 2FP Spectrum Analyzer Measurement, 3FP Amplitude Correction and Limit Lines, 4FP TOI and Harmonics, 5FP ACP 18 Carrier, 6FP TV Trigger and IQ Analyzer Enhancement, 7FP Zero Span, Register, Trace, and Spurious Enhancements |
N9060A-2FP | Spectrum Analyzer Measurement Application |
N9060A-3FP | Amplitude correction and Limit Lines |
N9060A-4FP | TOI and Harmonics |
N9060A2-4FP | TOI and Harmonics |
N9060A2FP | Spectrum Analyzer Measurement Application |
N9060B2FP | Spectrum Analyzer Measurement Application |
N9060B2FR | Spectrum Analyzer Measurement Application |
N9073A-1FP | Standard-based, one-button W-CDMA measurements; supports analog baseband analysis with Option BBA (BBIQ inputs) |
N9073A-2FP | Adds HSPA measurements; requires 1FP/1TP |
N9075A-2FP | Standard-based, one-button Mobile WiMAX measurements; supports analog baseband analysis with Option BBA (BBIQ inputs) |
NFE | Noise Floor Extension |
NUL | LO/IM nulling, Minimizes the LO feed-thru and intermodulation distortion |
P03 | Preamplifier, 100 kHz to 3.6 GHz |
P08 | 8.4 GHz Preamplifier |
P50 | Preamplifier, 50 GHz |
PC4 | Upgrade to dual core processor with removable solid state drive |
PC5 | Single core 64-bit performance processor, 4GB RAM, removable SSD |
PFR | Precision frequency reference 10 MHz |
PLUS | Includes: N9060A 3 TO 7FP, N9068A 2FP, N9069A 1 AND 2FP, N9071A 2 AND 3FP, N9072A 2FP AND 2TP, N9073A 1FP, 1TP, 2 AND 3 FP, A TO DFP, N9075A 2FP, N9076A 1FP, N9077A 2FP, N9079A 1 AND 2FP, N9080A 1FP, N9082A 1FP |
PRC | Portable configuration |
RTL | Real-time link |
T03 | 9 kHz to 3 GHz Tracking Generator Frequency |
YAS | Y-axis screen video output |
- Agilent N9020A, MXA X-Series Configuration Guide
- Agilent N9030A, N9020A, N9010A, N9000A X-Series Getting Started and Troubleshooting Guide