3458A Keysight Technologies Multimeter

New
$14,311.00
Free Shipping
 

Features:

  • 8 1/2 Digits
  • Measure with confidence with up to 8 ppm 1-year DCV accuracy (4ppm with option 002)
  • Maximize productivity with fast measurement speeds up to 100K readings/s
  • Up to 148K reading memory for prolonged data logging (extended memory now included in all new 3458A effective 10/2019)
  • DCV and ACV, DCI and ACI, Frequency, Temperature
  • 2- and 4-wire Resistance
  • Maximum sensitivity: 10 nV
  • Programmable integration times from 500 ns to 1 sec
  • Two-source (10 V, 10 kΩ) calibration, including AC
  • Self-adjusting, self-verifying auto-calibration for all functions and ranges, including AC
  • Multimeter Language (ML) compatible
  • GPIB

The Keysight 3458A, 8.5 digit multimeter, has a 30-year industrial-benchmark legacy for remarkable DC accuracy and stability. The redesigned 3458A multimeter also has standard lab 8.5-digit precision with leading-edge DCV linearity accuracy, the lowest internal noise, and it is RoHS compliant.

The 3458A is recognized the world over as the standard in high-performance digital multimeters, provides both speed and accuracy in the R&D lab, on the production test floor, and in the calibration lab. The Keysight 3458A is simply the fastest, most flexible, and most accurate multimeter ever offered by Keysight Technologies. In your system or on the bench, the Keysight 3458A saves you time and money with unprecedented test system throughput and accuracy.

  • Measure with confidence with up to 8 ppm 1-year direct current voltage (DCV) accuracy (4 ppm with option)
  • Maximize productivity with fast measurement speeds up to 100,000 readings/s
  • Prolonged data logging with up to 148,000 reading memory (now comes as standard)
  • Self-adjusting and self-verifying auto-calibration capability
  • Code compatible with previous version; RoHS compliant

With seven-function measurement flexibility and a convenient front panel, the 3458A enables:

  • faster test system startup, faster test throughput, and longer system up-time
  • usage as a calibration lab standard through its extraordinary linearity, low internal noise, and very high stability
  • high-resolution digitizing with 16- to 24-bit resolution, up to 12 MHz bandwidth path, high sampling rate, and very low < 100 ps jitter performance
More Information
ManufacturerKeysight Technologies
ConditionNew
AC Voltage1 kV
DC Voltage1 kV
Resolution8.5
TypeBench
Options
002High stability 4 ppm per year reference
909Rack flange and front handle kit
A6JANSI Z540-1-1994 Calibration
H01Special 1000 vrms ac maximum input voltage
OGCPrecision calibration, intended for metrology use only
Looking for other manuals? Search all of our available manuals here.