8654A Agilent RF Generator

Used

Additional Features:

  • Frequency range: 10 MHz to 520 MHz
  • Frequency accuracy is ±2% after 30 minute warm-up
  • Stability is 0.002% after a 1 hr warm-up.
  • Internal oscillators provide both AM and FM at 400 Hz and 1 MHz.
  • Front-panel meter accurately indicates AM percentage from 0 to 70%.
  • Output power range is from +13 dBm to -100 dBm with an accuracy of ±1 dB.
  • Level flatness is ±1 dB.
  • AM modulation has a range of 0 to 80% with less than 4% distortion.
  • FM peak deviation has a range of 0 to greater than 0.1%.

The Agilent 8654A is a Signal Generator that is low in cost, solid-state, and provides a calibrated output level over the frequency range of 10 MHz to 520 MHz in 6 bands.

More Information
ManufacturerAgilent, HP, Keysight
ConditionUsed
Frequency520 MHz
Looking for other manuals? Search all of our available manuals here.