M300RT Rod L Electronics HiPot

Used

Additional Features:

  • Insulation Resistance Detection: Up to 4000 megaohms
  • Maximum Output Voltage: 50 to 500 Volts DC, user-adjustable
  • Output Voltage Ramp Rate: 50 V/sec to 5000 V/sec, user-adjustable
  • Test Time: 1 to 180 seconds, user-adjustable
  • Arc Detection: Yes
  • End-of-Test Shutdown Time: 2 milliseconds
  • Line Input Voltage: 115/230 Volts AC, 44-66 Hz
  • Maximum Line Input Power Required: 300 Watts
  • Compatible with ROD-L HiPot and ground bond testers
  • Tests in compliance with UL, VDE, IEC, and MIL STD 202 standards
  • Performs high voltage shutdown and device-under-test discharge within 2 milliseconds of the end of the test
  • Performs rapid discharge of the device-under-test (DUT) following shutdown
  • Includes a fully-automatic test cycle
  • Signals when tester is ready, chassis ground is good, test is progressing, and test has passed or failed
  • Includes rear-panel presets for voltage ramp rate, test time, and insulation resistance trip point
  • Includes switch-selectable ramp-rate and test-time combinations
  • Includes arc detection
  • May be interconnected with the M25 ground bond tester or any ROD-L HiPot tester to facilitate sequential testing
  • Verifies existence of 0.5 Ohms or less (while applying 1.5 VAC) during chassis ground monitoring
  • Shuts down the high voltage with audible and visible failure alarms upon loss of acceptable safety ground continuity
  • Inhibits high voltage if the security chassis ground is not secure
  • Includes a front panel outlet for the device-under-test that prevents operator exposure to high voltage during the test
  • Includes visual and audible alarms for detection of arcs, low insulation resistance, and ground fault failures

Now you can perform safe, rapid and efficient insulation resistance testing up to 4000 megaohms at 500 VDC with the ROD-L Electronics model M300RT. The model M300RT insulation resistance tester performs both insulation resistance and ground continuity testing in compliance with the UL, VDE, BSI, IEC, and MIL STD 202 test standards. These standards help limit your exposure to product liability claims and risk of producing electrically unsafe products.

This tester also discharges the device-under-test (DUT) within 2 ms in order to further assure that no serious harm will come to the operator or the device-under-test while high voltage is present. In addition, this tester comes with a special front-panel high voltage outlet (rated at 8 kV) that you can use to connect your devices-under-test to the tester without exposure to high voltage cabling clips.

More Information
ManufacturerRod L Electronics
ConditionUsed
Looking for other manuals? Search all of our available manuals here.