MFTK-MM850-SM1550 Fluke Networks Fiber

New
$25,702.99
Free Shipping
 

Fluke Networks MFTK-MM850-SM1550 MultiFiber Pro Multimode and Singlemode MPO Kit with 850 LED and 1550 laser sources

Features:

  • 850 nm Multimode and 1550 nm Singlemode MPO trunk testing kit
  • Automatic scanning and test of all fibers in MPO connectors with “Scan All” function
  • Eliminates the need for fan-out cords when testing MPO fiber trunks
  • Automatic detection and analysis of standard 8, 10, and 12 fiber links
  • Encircled Flux compliant at bulkhead
  • Polarity agnostic referencing 

Kit Includes:

  • MultiFiber Pro Power Meter, 850 nm LED light source, 1550 nm laser light source, Multimode test cords (1 unpinned/unpinned; 1 unpinned/pinned; 2 pinned/pinned), Singlemode test cords (1 unpinned/unpinned; 1 unpinned/pinned; 2 pinned/pinned), 2 MPO adapters, 2

MultiFiber Pro Optical Power Meter and Source is the only fiber tester that can certify MPO fiber trunks without the use of fan-out cords.

This singlemode and multimode MPO fiber testing kit eliminates the complexity of polarity issues, and it makes cassettes easier to test in the field.

Whether it is using 10 Gbps preterminated MPO fiber trunks or planning for next-generation 40/100 Gbps Ethernet performance, data centers are standardizing on an MPO connector solution.

Typical data center fiber installation means time-consuming, manual and imprecise MPO validation. MultiFiber Pro Optical Power Meter and Source is 90 percent faster than single fiber cable certification because it measures power loss and validates polarity on 12 fibers in a single connector— reducing test time from weeks to days.

MultiFiber Pro 850nm LED Light Source

MultiFiber Pro takes the complexity out of testing MPO trunks for loss and polarity. With an on-board MPO connector, it is the first tester to automate the MPO fiber-trunk testing process without using a fan-out cord. The power meter/light source boasts industry-first functions such as automatic scanning of all twelve fibers and display of test results in an easy-to-read bar graph. These innovative features allow MultiFiber Pro kits to eliminate the complexity of testing MPO trunks, making it 90 percent faster than the traditional simplex test methods.

MultiFiber Pro Unique Capabilities

“SCAN ALL” Function

Scan All function in the MultiFiber Pro Power Meter automatically scans and tests all 12 fibers in MPO connectors – taking just 6 seconds to complete all loss or power measurements. This feature automates the testing of MPO terminated fibers and eliminates the time consuming and manual process of moving the tester from fiber to fiber while using fan-out cords.

Built-in Polarity Verification

The simple purpose of any polarity scheme is to provide a continuous connection from the link’s transmitter to the link’s receiver. For array connectors, TIA-568-C.0 defines three methods to accomplish this. Deployment mistakes are common because these methods require a combination of patch cords with different polarity types. The polarity measurement of MultiFiber Pro allows the user to test individual patch cords, permanent links, and channels for correct polarity.

On-board MPO connector

The MPO connector on both the Optical Power Meter and Light Source eliminates the use of costly and complicated fan-out cords to test MPO fiber trunks.

Simple User Interface

The MultiFiber Pro simplifies the task of simultaneously presenting polarity, power, and loss results for 12 fibers. The power meter enables the users to easily comprehend the measurement results of 12 fibers simultaneously. The light source identifies each fiber within the MPO connector being tested. Any individual measurements that fail the test limit is identified to allow root-cause analysis. This powerful yet straightforward test set enables everyone to become a fiber testing expert increasing efficiency in testing data center projects.

Select an Individual Fiber

Drilling down to a single fiber during testing and troubleshooting is always a challenge in data centers. MuliFiber Pro can troubleshoot a single fiber within an MPO trunk to provide a single fiber test result. This tincreases MPO connector verification and troubleshooting flexibility with more precise, per-fiber data and reporting.

On-board Shuttered MPO Connector

Uncovered ports can put cabling, equipment and testers at risk for contamination and affect performance. Ensuring a covered connection on your tester can protect it from dirt and dust. MultiFiber Pro makes it easy by shuttering the MPO connector for greater test reliability and peace of mind.

Easy Reporting

The MultiFiber Pro Power Meter stores up to 3,000 test results internally which can be uploaded to a PC using the LinkWare™ 7 Cable Test Management Software. LinkWare 7 allows you to manage test results, edit cable ID’s, print professional reports and even export the data into spreadsheet formats.

Kits for Every Need

MultiFiber Pro is available in several convenient kit configurations to meet all your cleaning, inspection and verification testing needs. Some kits include:

Fiber Inspection - FiberInspector™ Pro

The FiberInspector Pro is the ultimate inspection tool. Its 3.5” screen provides a larger image from its dual magnification probe. The small probe fits in the palm of your hand and can be switched between 250x and 400x magnification with the turn of a dial. The FiberInspector Pro and optional MPO tip complement the MultiFiber Pro test set, provide a comprehensive kit for cleaning, inspection and testing of MPO connected fibers and cassettes.

Fiber Cleaning - IBC™ OneClick Cleaners

Cleaning is critical. Fluke Networks’ OneClick Cleaners instantly clean fiber optic bulkhead connectors and end-faces. Just push the tool tip to engage cleaning action and pull back on the wheel – it’s that simple. The MPO OneClick Cleaner is bundled with the MultiFiber Pro kits to ensure that you have the best cleaning tool from the beginning.

Manufacturer Specs

Environmental

  • Operating temperature  -10ºC to +50ºC
  • Storage temperature  -20ºC to +50ºC
  • Operating humidity  95% (10ºC to +35ºC) non-condensing 75% (35ºC to +45ºC) non-condensing
  • Uncontrolled <10ºC
  • Operating altitude 4,000 m
  • Storage altitude  12,000 m
  • Vibration  Random 2 G, 5 Hz to 500 Hz

Optical Power Meter (Specifications apply at 23ºC (73ºF), unless otherwise noted.)

  • Detector type InGaAs
  • Calibrated wavelengths  850 nm, 1300 nm, 1310 nm, 1550 nm
  • Measurement range  0 dBm to -50 dBm
  • Test time  6 seconds
  • Power measurement linearity  ±0.1 dB2
  • Power measurement uncertainty  ±0.35 dB2
  • Power measurement repeatability  < 0.10 dB2
  • Display resolution, dB or dBm  0.01
  • Power display units dBm, mW, µW
  • User-selectable limit for loss 0.05 dB to 50.0 dB, in increments of 0.05 dB up to 10.0 dB and 0.1 dB up to 50.0dB 
  • Auto wavelength detection  Yes
  • Polarity detection  Detects A, B, C, and Corning Plug & Play™ Universal Systems polarities
  • 2 kHz detection  Yes
  • Record storage  3000 records, one fiber per record (250 12-fiber cables)
  • External interface  USB 2.0, full speed

Optical connector 

  • MPO interface for 12-fiber, unpinned plugs. Compatible with 62.5 µm, 50 µm, and singlemode fibers. Connector has a self-closing, protective cover.

 

  • Power requirement  2 AA alkaline batteries
  • Battery life3  30 hours (typical)
  • Automatic power-off  10, 20, 30, or 60 minutes (can be disabled by the user)
  • Low battery warning  Low battery icon blinks
  • Emitter type  Emitter type
  • Wavelength  1310 nm ±20 nm
  • Spectral width (FWHM)  2 nm typical, 5 nm maximum
  • Minimum output power  ≥ -1 dBm
  • Power output stability  ±0.25 dB over 8 hours5
  • Laser safety IEC 60825-1:Class 1

Optical connector 

  • MTP/MPO interface for 12-fiber, unpinned plugs. Compatible with 9 µm fibers, APC only. Connector has a self-closing, protective cover.

 

  • Modes  2 kHz modulated, auto wavelength/td>
  • Power requirement  2 AA alkaline batteries
  • Battery life6  >30 hours (typical)
  • Automatic power-off  10, 20, 30, or 60 minutes (can be disabled by the user)
  • Low battery warning  Low battery icon blinks

Tech Specs

Fiber Optic Test Kits - OLTS Template

  • Fiber Type Multi mode, Single mode
  • Wavelength 1550, 850
  • Has Memory Yes
  • Tester Type Test kit

Test Equipment General Attributes

Unique Features

  • 1550 nm Singlemode Kit
  • 1550 nm Light Source
  • 850 nm Light Source

 

  • Interfaces I/O USB 
  • Product Weight 309 GRAMS (0.681 LBS)
  • Battery Type AA 
  • Power Supply Voltage Battery Powered
  • Country of Origin Lithuania
  • Other Information
  • Size:: 5.8 in x 3.2 in x 1.6 in

Ships With:

  • MultiFiber Pro Power Meter
  • 850 nm LED light source
  • 1550 nm laser light source
  • Multimode test cords (1 unpinned/unpinned; 1 unpinned/pinned; 2 pinned/pinned)
  • Singlemode test cords (1 unpinned/unpinned; 1 unpinned/pinned; 2 pinned/pinned)
  • 2 MPO adapters
  • 2 APC MPO adapters
  • Magnetic Strap Attachments
  • Carrying case